User's Manual

DRAFT TrimTrac 1.5 Technical Manual v0.3ab 154
Extended1.5 Read/ Write Parameters :
Parameter Unit/Notes Default Messages Commands
Motion Counter Threshold Counter (1-2000). Note: Number of motion counts per
second required before motion counter is set.
10
Scheduled Hours 0=Disabled; 1=Enabled 0
Daily Start Time, T27 In Seconds (0 – 86399) after 12:00AM UTC. 0
Work Day Length, T28 In Seconds (0 – 86400) Note: Number of seconds worked
each workday.
43200
First Work Day of Each
Week
0=Sunday; 1=Monday; 2=Tuesday; 3=Wednesday;
4=Thursday; 5=Friday; 6=Saturday (All relative to UTC)
1
Number of Work Days per
Week
1= One Day; 2=Two Days; 3=Three Days; 4=Four Days;
5=Five Days; 6=Six Days; 7=Seven Days. Note: Number
of consecutive workdays each week.
5
Runtime Meter Motion-
based
0=Disabled; 1=Enabled 0
Runtime Meter LPA-
based
0=Disabled; 1=Enabled 0
Runtime Meter Motion-
based Countdown, T29
In Hours (0=No Countdown, 1-990) 0
Runtime Meter LPA-
based Countdown, T30
In Hours (0=No Countdown, 1-990) 0
Automatic Message Log
Dump
0=Disabled; 1=Enabled. Note: Causes previously unsent
messages to be transmitted upon re-entering GSM network
coverage.
0
GPS Fix Rate 0=GPS operation during FIX State only; 1=1Hz GPS
operation except while stationary. Note: 1 Hz used for
Geofence monitoring and last known position reporting.
0
LPA Input Arming Delay,
T31
In Seconds (0-990). Number of seconds after initial
contact closure before LPA becomes “Armed”.
0
>STKZ
>QTKZ
>RTKZ
AT+CTKZ
Table 88, Extended1.5 Read/Write Parameters.