User's Manual

DRAFT TrimTrac 1.5 Technical Manual v0.3ab 131
RESP_EXT_APP_CONFIG
This is the response message to the SET_EXT_APP_CONFIG and
QUERY_CONFIG message containing the Extended Application Parameter
values.
>RTKABCCCCCCDEFFFFFFGGGGGGHIJJJKKKLLMMNNO;ID=YYYYYYYY;
*ZZ<
A
TrimTrac Configuration Set: ‘X’ = Extended Application
Parameters
B
Scheduled Reporting
Mode. 0=None; 1=Daily; 2=Weekly
CCCCCC
Scheduled Report Time,
T18. In Seconds (0-604799). Note: This
is either the seconds into the day or into the week for the device to
schedule transmission of a STATUS_MESSAGE plus the most
recently logged
POSITION_REP, if any, when this feature is enabled.
If Scheduled
Reporting Mode is set “0=None”, then enter 0.
D
In-Motion Polling. 0=Disabled; 1=OnDemand while in Motion. Note:
If set to “1=OnDemand while in Motion”, the unit is able to receive
and process data messages
ONLY while in motion regardless of
current state.
E
Anytime Polling. 0=Disabled; 1=Duty-Cycled while
in IDLE State;
2=Anytime OnDemand. Note: If set to “2=Anytime
OnDemand”, the unit is able to receive and process data
messages regardless of motion, current state or how In-Motion
Polling is set. If set “1=Duty-Cycled”, unit is able to receive and
process data messages while in QUERY or whenever while
Polling Duty-Cycle On-Time, T20, is running.. Default 0. Note:
In-Motion Polling is treated as always “1=Enabled” when Anytime
Polling is set to “2=Anytime OnDemand”.
FFFFFF
Polling Duty-Cycle Frequency,
T19. In Seconds (10-999990).
Note: Determines how frequently the Polling Duty-Cycle On-Time,
T20, timer is started if and only if the Anytime Polling is set
to
“1=Duty-Cycled while in
IDLE State” and device is NOT in
motion.
Default 3600. Note: Determines the frequency at which the
QUERY state is enabled while in the IDLE state if and only if the
Anytime Polling is set to “1=Duty-Cycled”.
GGGGGG
Polling Duty-Cycle On-Time,
T20. In Seconds (0, 10-3600). Note:
Determines how long after expiration of Polling Duty-Cycle
Frequency, T19, timer that
the unit is able to receive and process data
messages. A value of zero
causes the QUERY Timeout, T5, value to
be used. Default 60.
H
Query Hold Flag. 0=Disabled; 1=Enabled.
Note: Unit attempts to
reconnect to the GSM network if the connection is lost during the
QUERY state prior to the expiration of QUERY Timeout,
T5.
I
Reserved. 0=Formerly “Extended
Motion Detection” in TrimTrac
1.0 Not used in TrimTrac 1.5.
JJJ
Position Report Transmit Attempts,
N1. 0=Until T3 Expires; 1-
255=Number of Tx Attempts.