User's Manual
DRAFT TrimTrac 1.5 Technical Manual v0.3ab 130
RESP_APP_CONFIG
This is the response message to the SET_APP_CONFIG and QUERY_CONFIG
messages containing the Application Parameter values.
>RTKABBBBBBCCCCCCDDDDDDEEEEEEFFFFFFGGGTTHIJKLLLLMMMMMMNP
P;ID=YYYYYYYY;*ZZ<
A
TrimTrac Configuration Set: ‘A’ = Application Parameters
BBBBBB
IDLE Timeout, T1. In seconds (10 – 999990)
CCCCCC
FIX Timeout, T2. In seconds (10 – 3600)
DDDDDD
TRANSMIT Timeout, T3. In seconds (10 – 3600)
EEEEEE
DELAY Timeout, T4. In seconds (10 – 86400)
FFFFFF
QUERY Timeout, T5. In seconds (10 – 3600)
GGG
Almanac Timeout, T6. In hours (10 – 990)
TT
Static Motion Filter Timeout, T7. In seconds (0 – 90). Note: T7 is used
exclusively
while in the IDLE state; however, it is superseded by the
Dynamic Filter Timeout,
T21, whenever Anytime Polling is:
A.
Set “2=Anytime OnDemand”; OR
B. Set “1-Duty-Cycled” and Polling Duty-Cycle On-Time, T20, is
running.
Always set Static Motion Filter Timeout, T7, greater than or equal to Static
Motion Filter Counter, N3.
H
Motion Report Flag. 0=None; 1=Report Motion in IDLE (before
attempting new GPS fix)
I
Report Delay Flag. 0=Transmit All Messages; 1=Transmit Alert, Query
response and Scheduled messages only; 2=Transmit Motion-related AND
Alert, Query response and Scheduled messages only; 3= Transmit IDLE
Timeout, T1, Status Messages AND Alert, Query response and Scheduled
messages only; 4=Start/Stop Reporting; 5=Log 5 messages, transmit next;
6=Log 10 messages, transmit next
J
Diagnostics Mode. 0= None; 1= LED
K
Communication Mode. 0= SMS; 1= GPRS; 2=AutoSelect
LLLL
Battery Change Week: GPS Week Number, always 4 digits
MMMMMM
Battery Change Time: Seconds into GPS Week, always 6 digits
N.PP
Firmware Version: Numeric String
YYYYYYYY
Unit ID. Always 8 alphanumeric characters, UPPER CASE ONLY
ZZ
Checksum.
Table 68, RESP_APP_CONFIG Message