DRAFT TrimTrac 1.5 Technical Manual v0.3ab 121
SET_MODULE_APP_CONFIG
This message is used by the server to set the Application Parameter Values
associated with the Vehicle Adapter and Control Modules. When received the
TrimTrac 1.5 will send a RESP_MODULE_APP_CONFIG message in response.
TrimTrac 1.5s not equipped with a MODULE ignore the message.
>STKABBBBBBCCCCCCDDDDDDEEEEEEFFFFFFGGGGGGHHHHHHIIIJJJK
KKLMN;PW=PPPPPPPP;ID=YYYYYYYY;*ZZ<
A
MODULE-only Configuration Set: ‘Y’ = MODULE-only
Parameters
BBBBBB
HPA Idle Timeout, T11. In Seconds (10-999990) Default 10
CCCCCC
MPA Idle Timeout, T12. In Seconds (10-999990). Default 10
DDDDDD
HPA Delay Timeout, T13. In Seconds (10-86400). Default 10
EEEEEE
MPA Delay Timeout, T14. In Seconds (10-86400). Default 10
FFFFFF
HPA Transmit Timeout, T15. 0=Infinity; Else in Seconds (10-
999990). Default 0
GGGGGG
MPA Transmit Timeout, T16. 0=Infinity; Else in Seconds
(10-999990). Default 120
HHHHHH
HPA Query Timeout, T17. In Seconds (10-3600). Default 60
III
HPA Transmit Attempts, N5. 0=Until T15 Expires; 1-
255=Number of Tx Attempts before T15 expires. Default 0.
JJJ
MPA Transmit Attempts, N6. 0=Until T16 Expires; 1-
255=Number of Tx Attempts before T16 expires. Default 0
KKK
LPA Transmit Attempts, N7. 0=Until T3 Expires; 1-
255=Number of Tx Attempts before T3 expires. Default 0
L
HPA Mode. 0=Automatic; 1=Disabled; 2=Network
Acknowledgement; 3= Monitor-only. Default 0
M
0=Automatic; 1=Disabled; 2=Network Acknowledgement; 3=
Monitor-only.
WARNING: Before inserting a Vehicle Adapter or Control
Module:
A) Connect the red (+) and black (-) wires to a 9-32 VDC
power source and install a 100k Ohm resistor across the
yellow wires; OR
B) Return MPA Mode to its default setting “1=Disabled”.
Default 1.
N
LPA Mode. 0=Automatic; 1=Disabled; 2=Network
Acknowledgement; 3= Monitor-only (regardless of motion).
Default
0
PPPPPPPP
Security Password
. Always 8 alphanumeric characters, UPPER
CASE ONLY.
. Default 00000000
YYYYYYYY
Unit ID. Always 8 alphanumeric characters, UPPER CASE ONLY
ZZ
Checksum.
Table 58, SET_MODULE_APP_CONFIG Message