User's Manual

DRAFT TrimTrac 1.5 Technical Manual v0.3ab 115
255=Number of Tx Attempts. Default 1.
KKK
Status Message Transmit Attempts,
N2. 0=Until T3 Expires; 1-
255=Number of Tx Attempts. Default
1.
LL
Static Motion Filter
Counter, N3. In Seconds (1-90). Note: This
parameter is used only while Static Motion Filter Timeout,
T7, is
running in the IDLE State. It is superseded by the Dynamic
Motion Filter Counter, N4 whenever:
A. Anytime Polling is set “2=Anytime OnDemand”;
OR
B. Polling Duty-Cycle On-Time, T20, is running due to Anytime
Polling being set “1=Duty-Cycled”.
Always set Static Motion Filter Counter, N3, equal to or less than
Static Motion Filter Timeout, T7. Default
10.
MM
Dynamic Filter Timeout,
T21. In Seconds (1-90). Note: T21
applies in TRANSMIT, QUERY and DELAY States. Also
applies in IDLE if:
A. Anytime Polling is set “2=Anytime OnDemand”; OR
B. Polling Duty-Cycle On-Time, T20, is running due to Anytime
Polling being set “1=Duty-Cycled”.
WARNING: Dynamic Filter Timeout, T21, must always be set
equal to or greater than Dynamic Motion Filter Counter, N4; else
the unit may not exit QUERY state. Default
20.
NN
Dynamic Motion Filter
Counter, N4. In Seconds (1-90). Note:
This parameter is enabled only when Dynamic Filter Timeout,
T21, is active.
WARNING: Dynamic Motion Filter Counter, N4, must always be set
equal to or less than the setting for Dynamic Filter Timeout, T21; else
the unit may not exit QUERY state.. Default
10.
O
Motion Sensor
Override. 0=Normal; 1=Motion Always; 2=Motion
Never.
Note: Overrides the motion sensor if set to a value other
than “0=Normal”..
Default 0.
PPPPPPPP
Security Password
. Always 8 alphanumeric characters, UPPER
CASE ONLY.
. Default 00000000
YYYYYYYY
Unit ID. Always 8 alphanumeric characters, UPPER CASE ONLY
ZZ
Checksum.
Table 51, SET_EXT_APP_CONFIG Message