User's Manual

DRAFT TrimTrac 1.5 Technical Manual v0.3ab 100
AT+CTKZ?
CTKZ: <Motion Counter Threshold>,<Scheduled Hours>,<Daily Start Time,
T27>,<Work Day Length, T28>,<First Work Day of Each Week>,<Number of
Work Days per Week>,<Runtime Meter Motion-based>,<Runtime Meter LPA-
based>,<Runtime Meter Motion-based Countdown, T29>,<Runtime Meter LPA-
based Countdown, T30>,<Automatic Message Log Dump>,<GPS Fix
Rate>,<LPA Input Arming Delay, T31>,<Geofence Type>
OK
<Motion Counter Threshold> Counter (1-2000).
<Scheduled Hours> 0=Disabled; 1=Enabled.
<Daily Start Time, T27> In Seconds (0 – 86399) after 12:00AM UTC..
<Work Day Length, T28> In Seconds (0 – 86400).
<First Work Day of Each
Week >
0=Sunday; 1=Monday; 2=Tuesday;
3=Wednesday; 4=Thursday; 5=Friday;
6=Saturday (All relative to UTC).
<Number of Work Days per
Week>
1= One Day; 2=Two Days; 3=Three Days;
4=Four Days; 5=Five Days; 6=Six Days;
7=Seven Days.
<Runtime Meter Motion-
based >
0=Disabled; 1=Enabled.
<Runtime Meter LPA-based> 0=Disabled; 1=Enabled.
<Runtime Meter Motion-
based Countdown, T29>
In Hours (0=No Countdown, 1-990).
<Runtime Meter LPA-based
Countdown, T30>
In Hours (0=No Countdown, 1-990).
<Automatic Message Log
Dump>
0=Disabled; 1=Enabled.
<GPS Fix Rate> 0=GPS operation during FIX State only; 1=1Hz
GPS operation except while stationary.
<LPA Input Arming Delay,
T31
In Seconds (0-990).
<Geofence Type> 0=Boundary Crossing; 1=Inclusive; 2=Exclusive.
Default
1
Table 40, AT+CTKZ? Query