AT+CTKZ Daily Hours, Runtime & Other Extended Settings
The AT+CTKZ command configures the Scheduled Hours of Operation, Runtime
Meter and other operation parameters as defined below.
AT+CTKZ=<Motion Counter Threshold>,<Scheduled Hours>,<Daily Start Time,
T27>,<Work Day Length, T28>,<First Work Day of Each Week>,<Number of
Work Days per Week>,<Runtime Meter Motion-based>,<Runtime Meter LPA-
based>,<Runtime Meter Motion-based Countdown, T29>,<Runtime Meter LPA-
based Countdown, T30>,<Automatic Message Log Dump>,<GPS Fix
Rate>,<LPA Input Arming Delay, T31>,<Geofence Type>
OK
<Motion Counter
Threshold
>
Counter (1-2000). Default: 10
<Scheduled Hours> 0=Disabled; 1=Enabled. Default: 0
<Daily Start Time, T27> In Seconds (0 – 86399) after 12:00AM UTC..
Default:
0
<Work Day Length, T28> In Seconds (0 – 86400). Default: 43200
<First Work Day of Each
Week >
0=Sunday; 1=Monday; 2=Tuesday; 3=Wednesday;
4=Thursday; 5=Friday; 6=Saturday (All relative to
UTC). Default: 1
<Number of Work Days per
Week>
1= One Day; 2=Two Days; 3=Three Days; 4=Four
Days; 5=Five Days; 6=Six Days; 7=Seven Days.
Default:
5
<Runtime Meter Motion-
based >
0=Disabled; 1=Enabled. Default: 0
<Runtime Meter LPA-
based>
0=Disabled; 1=Enabled. Default: 0
<Runtime Meter Motion-
based Countdown, T29>
In Hours (0=No Countdown, 1-990). Default: 0
<Runtime Meter LPA-based
Countdown, T30
>
In Hours (0=No Countdown, 1-990). Default: 0
<Automatic Message Log
Dump
>
0=Disabled; 1=Enabled. Default: 0
<GPS Fix Rate> 0=GPS operation during FIX State only; 1=1Hz
GPS operation except while stationary. Default: 0
<LPA Input Arming Delay,
T31
In Seconds (0-990). Default: 0
<Geofence Type> 0=Boundary Crossing; 1=Inclusive; 2=Exclusive.
Default
1
Table 39, AT+CTKZ Assignment
Default: AT+CTKZ=10,0,0,43200,1,5,0,0,0,0,0,0,0,1