User's Manual
DRAFT TrimTrac 1.5 Technical Manual v0.3ab 94
<Reserved>
0=Formerly “Extended
Motion Detection” in TrimTrac 1.0
Not used in TrimTrac 1.5.
Default 0
<Position Report Transmit
Attempts,
N1>
0=Until T3 Expires; 1-255=Number of Tx Attempts.
Default 1
<Status Message Transmit
Attempts,
N2>
0=Until T3 Expires; 1-255=Number of Tx Attempts. Default
1
<Static Motion Filter
Counter, N3>
In Seconds (1-90).
Note: This parameter is used only
while Static Motion Filter Timeout, T7, is running in
the IDLE State. It is
superseded by the Dynamic Motion
Filter Counter, N4 whenever:
A. Anytime Polling is set “2=Anytime OnDemand”;
OR
B. Polling Duty-Cycle On-Time, T20, is running due to
Anytime Polling being set “1=Duty-Cycled”.
Always set Static Motion Filter Counter, N3, equal to or
less than Static Motion Filter Timeout, T7. Default
10
<Dynamic Filter Timeout,
T21>
In Seconds (1-90).
Note: T21 applies in TRANSMIT,
QUERY and DELAY States. Also applies in IDLE if:
A. Anytime Polling is set “2=Anytime OnDemand”;
OR
B. Polling Duty-Cycle On-Time, T20, is running due to
Anytime Polling being set “1=Duty-Cycled”.
WARNING: Dynamic Filter Timeout, T21, must
always be set equal to or greater than Dynamic Motion
Filter Counter, N4; else the unit may not exit QUERY state.
Default
20
<Dynamic Motion Filter
Counter, N4>
In Seconds (1-90).
Note: This parameter is enabled only
when Dynamic Filter Timeout, T21, is active.
WARNING: Dynamic Motion Filter Counter, N4, must
always be set equal to or less than the setting for Dynamic
Filter Timeout, T21; else the unit may not exit QUERY
state.. Default
10
<Motion Sensor
Override
>
0=Normal; 1=Motion Always; 2=Motion Never.
Note:
Overrides the motion sensor if set to a value other than
“0=Normal”..
Default
0
Table 35, AT+CTKX Assignment
Default: AT+CTKX=0,0,0,0,3600,60,0,0,1,1,10,20,10,0