User's Manual

DRAFT TrimTrac Locator Technical Manual 35
SET_PROV_CONFIG
The SET_PROV_CONFIG message is used by the server application to set the
Communication values in the TrimTrac locator. When received by the TrimTrac
locator, the unit will send a RESP_PROV_CONFIG message in response.
>STKABBBBBBBBBBBBBBBBBBBBBBBB;PW=PPPPPPPP;ID=YYYYYYYY;
*ZZ<
A TrimTrac Configuration Set: ‘V’ = Application Provisioning
Parameters
BBBBBB
BBBBBB
BBBBBB
BBBBBB
Destination Address.Max. 24 characters including international
dialing “+” sign and country code. Field Padding is in spaces.
Default <Empty>
PPPPPPPP
Security Password. Always 8 digits. Default 00000000
YYYYYYYY
Unit ID. Unique unit identifier. Always 8 digits.
Default 00000000
ZZ Checksum
Table 15, SET_PROV_CONFIG Message
SET_GPS_CONFIG
The SET_GPS_CONFIG message is used by the server application to set the
TrimTrac GPS parameter values in the TrimTrac locator. When received the
TrimTrac locator will send a RESP_GPS_CONFIG message in response.
>STKABBCCCDDDEEEF;PW=PPPPPPPP;ID=YYYYYYYY;*ZZ<
A TrimTrac Configuration Set: ‘G’ = GPS Parameters
BB Elevation Mask. In degrees (0-90). Default 5
CCC PDOP Mask. In tenths of PDOP. Default 120
DDD PDOP Switch. In tenths of PDOP. Default 60
EEE AMU Mask. In tenths of AMUs. Default 20
F Dynamics Mode. Undefined = 0
Land = 1
Sea = 2
Air = 3
Stationary = 4
Automobile = 5.
Default 5
PPPPPPPP
Security Password. Always 8 digits. Default 00000000
YYYYYYYY
Unit ID. Unique unit identifier. Always 8 digits.
Default 00000000
ZZ Checksum.
Table 16, SET_GPS_CONFIG Message