User's Manual

DRAFT TrimTrac Locator Technical Manual 12
TrimTrac Locator Defaults
Introduction
The following sections set for the various factory default settings for the TrimTrac
locator. All such default settings can be changed to suit the particular application
requirements. While most of the settings can be configured or changed by
sending the appropriate SMS text messages over the GSM network, certain fields
such as the Device Identification number, Security Password and SIM PIN can
only be entered or changed while the device is connected to a PC using the
Provisioning Module. Please refer to the TrimTrac Application chapter beginning
on page 30 for detailed descriptions of each TrimTrac state.
Factory Default Settings
Parameter Unit/Notes Default
Unit ID Unique unit identifier.
Always 8 digits and can only
be changed using
Provisioning Module.
00000000
Destination
Address
Valid destination address for
SMS messages must be
entered prior to initial
deployment. Max. 24
characters including
international dialing “+” sign
and country code.
<Empty>
SIM PIN Entered only if required by
SIM card and can be entered
or changed using
Provisioning Module. Max. 4
digits.
<Empty>
Security Password Always 8 digits and must be
entered using Provisioning
Module prior to initial
deployment.
00000000
Idle Timeout, T1 In seconds (10 999999) 43200
Fix Timeout, T2 In seconds (10 999999) 300
Comm Timeout, T3 In seconds (10 999999) 120
Sleep Time, T4 In seconds (10 999999) 900
Query Time, T5 In seconds (10 999999) 60
Almanac Timeout,
T6
In hours (10 999) 168
Motion Timeout,
In seconds (5 99) 15