2
Figure 2.23 illustrates the power and I/O cable.
Figure 2.23 Power and I/O Cable (P/N 46598-00)
Note Trimble recommends installing the power and ground leads as
close to the battery as possible to ensure that the CrossCheck CDPD is
connected to the cleanest possible source of power.
1 Vbat Red Input Power 9-32V
2 GND Black
3 GND Green Chassis GND
4 GND
Blk/White
GND
5 White Ignition Sense Input
6 Blue Input 3
7 Purple Input 2
8 Orange Discrete Output 2
9
IP1
Input 1
10 Gray Discrete Output 1
11 Purple/White Input 0
12 Brown Discrete Output 0
4
6
8
10 12
1
2
3
57
9
11
14 16
Connector
Molex Micro-Fit 3.0 16-Pin
Molex P/N 43025-1600
Pins
Molex Female
templated Contact
Molex P/N 43030-0001
Side View
Yellow
XP1
IP0
XP0
IGN
IP3
IP2
XP2
13 Pulse 0 Brn/White Pulse Counter Input 0
14 Pulse 1 Gray/White Pulse Counter Input 1
15 Pulse 2 Orange/White Pulse Counter Input 2
16 8V AUX Red/White 8 VDC Auxiliary Input