User Manual
Table Of Contents
- CrossCheck® CDPD
- Warranties and Notices
- Regulatory Approvals
- Contents
- About this Manual
- Chapter 1 - Overview
- Chapter 2 - Installation
- Introduction
- Installing the CrossCheck CDPD Mobile Unit
- CrossCheck CDPD Connections
- Inspecting and Unpacking the Shipment
- Installer-Supplied Parts
- Mounting the CrossCheck CDPD
- Choosing the GPS Antenna Mounting Location
- Routing the GPS Antenna Cable
- Choosing a CDPD Cellular Antenna MountingLocation
- Caution – FCC RF Exposure requirements
- Magnetic Cellular Antenna (P/N 46721)
- Bulkhead Cellular Antenna (P/N 46730)
- Routing the Cellular Antenna Cable
- Connecting the Magnetic Cellular Antenna Cable
- Connecting the Permanent-Mount Cellular Cable
- Inputs (IP0 to IP3)
- Pulse Counting Inputs (Pulse 0 to Pulse 2)
- Outputs (XP0 to XP2)
- CrossCheck CDPD Power
- Installing the EchoLDX Kit
- Chapter 3 - Operation
- Appendix A - Specifications
- Reader Comment Form
CrossCheck CDPD Mobile Unit Manual
41
Installation
2
2.9.7
Pulse Counting Inputs (Pulse 0 to Pulse 2)
The CrossCheck CDPD also supports three pulse-counting inputs that
can be used in several applications. The circuit diagram is shown in
Figure 2.19.
Figure 2.20 Pulse Countin Input Circuit Diagram
Input Logic High:
Open circuit or V
in
> 2.4 VDC
Input Logic Low:
V
in
< 0.6 VDC
The inputs must remain in either state for at least
200 milliseconds before the CrossCheck CDPD
detects the input.
Input Current
(Max)
I
in
< 3 mA
1 mA is typical at 12 VDC.
Minimum Pulse
Width
500 microseconds
Input Protection:
Protected up to at least V
Batt
continuous
3K
330K
0.01µF
To logic
470pf
Input
100K
3.3V/0.5/A