User Manual
Table Of Contents
- CrossCheck® CDPD
- Warranties and Notices
- Regulatory Approvals
- Contents
- About this Manual
- Chapter 1 - Overview
- Chapter 2 - Installation
- Introduction
- Installing the CrossCheck CDPD Mobile Unit
- CrossCheck CDPD Connections
- Inspecting and Unpacking the Shipment
- Installer-Supplied Parts
- Mounting the CrossCheck CDPD
- Choosing the GPS Antenna Mounting Location
- Routing the GPS Antenna Cable
- Choosing a CDPD Cellular Antenna MountingLocation
- Caution – FCC RF Exposure requirements
- Magnetic Cellular Antenna (P/N 46721)
- Bulkhead Cellular Antenna (P/N 46730)
- Routing the Cellular Antenna Cable
- Connecting the Magnetic Cellular Antenna Cable
- Connecting the Permanent-Mount Cellular Cable
- Inputs (IP0 to IP3)
- Pulse Counting Inputs (Pulse 0 to Pulse 2)
- Outputs (XP0 to XP2)
- CrossCheck CDPD Power
- Installing the EchoLDX Kit
- Chapter 3 - Operation
- Appendix A - Specifications
- Reader Comment Form
2
Installation
26
CrossCheck CDPD Mobile Unit Manual
To mount the Miniature Bulkhead GPS antenna with Flange:
1. Drill holes in the mounting surface using the antenna mounting
template shown in Figure 2.9.
Figure 2.9 Mounting Hole Dimensions
2. Slip the antenna through the larger hole in the center of the hole
pattern and rotate the antenna until the four holes in the antenna
mounting flange are aligned to the hole circle.
3. Secure the antenna with the four screws, lock washers, and nuts.
4. Connect the TNC connector on the antenna cable to the TNC
connector on the antenna.
5. Route the cable to the CrossCheck CDPD mounting location.
Use cable ties to secure the cable along the routing path.
For detailed cable routing guidelines, see Routing the GPS Antenna
Cable on page 2-30.
7.6 cm
(3.0 in)
19 mm
(0.75 in)
3.8 mm
(0.15 in)