User's Manual

SPSx50 Modular GPS Receiver User Guide 159
Troubleshooting F
Receiver does not log
data.
Insufficient memory. Delete old files by holding down
for 30 seconds.
Delete the old files by using the
delete and purge functions available
in the Data Logging menu (see
page 85) of the web interface.
Data Logging option is
disabled.
Order the data logging option from
your local Trimble dealer. Data
logging is disabled as standard on all
SPS GPS receivers. Check your
original purchase order or the
receiver configuration using the web
interface to see if data logging is
enabled on your receiver.
The receiver is tracking fewer
than four satellites.
Wait until the receiver display shows
that more than four satellites are
being tracked.
The internal memory needs to
be reformatted
Press for 30 seconds.
The receiver is not
responding.
Receiver needs soft reset. Turn off the receiver and then turn it
back on again.
Receiver needs full reset. Press for 30 seconds.
Issue
Possible cause Solution