User Manual
3. Press the enter button to confirm the selected rotation speed.
Changing the Grade Value
The grade value for both axes can be changed using two methods—standard
and quick-change. The standard method is used for entering small changes in
the grade value. The quick-change method is used for setting grade to zero
and entering large changes in the grade value.
Standard Method
Note: The last-entered grade value for each axis appears in the two-way radio
remote control’s LCD. If you are using a one-way remote control, you must
look at the laser’s LCD for this information.
Note: The grade value can be quickly set to 0.000% by simultaneously
pressing and releasing either the laser’s or the radio remote control’s up and
down buttons for the axis you want to change.
1. Select the desired grade axis (∠ or ∠) from the menu using the mode
button.
2. Press and hold the up or down button for the axis you want to change
until the desired grade value appears in the laser’s LCD. If you are using a
two-way radio remote control, this information appears in the radio
remote control’s LCD.
Note: The speed of the grade value change increases with the amount of time
the button is held down.
Note: Grade values on the radio remote control are displayed in thousandths
of a percents.
Note: All changes to the axis-alignment rotation made prior to changing the
grade value using the standard method will be retained.
Quick-Change Method
1. Select the desired grade axis (∠ or ∠) from the menu using the mode
button.
2. Simultaneously press and hold the up and down buttons for the axis you
want to change to set the grade value to 0.000%.
Note: The grade value for the ∠ axis increases in 1.00% increments. The
grade value for the ∠ axis increases in 5.00% increments.
3. Continue pressing and holding the up and down buttons until the desired
grade value appears in the laser’s LCD. If you are using a two-way radio