User Manual

12
The RC603 Service menu offers additional features:
RF IR options
Press and release button 4toconrmtheselectionandselectoneofthefollowingoptions:
RFOn;IRauto=>Radioonalltimes;IRwillbeactivatedautomaticallyafterradioconnection
has been lost.
RFOff;IROn=>RadioturnedOff;IRalwaysactivated
RFOn;IROff=>RadioturnedOn;IRalwaysOff
RF Connectivity
Press and release button 4togetastatusofthecurrentRadioconnectivity.
Special Features - Vertical Setup
Z-Axis Automatic Spot Align
TheSpotFinderSF601guidestheplumbbeamtothe
targetpointinthehorizontalaxis,whiletheZ-axisgrade
value will be maintained. Used for rst and second
day alignment (pipe laying applications). Using Spot
Alignment,theplumbbeamcanbealignedautomatically
toonedirectionhub(upto80m(260ft)locatedinfront
of the plumb beam.
1.Setupthelaseroverthestartpoint,e.g.,attherst
manhole ring.
2.Adjustthedisplaybubbletothecenteredposition.
3.TurnonandattachtheSF601SpotFinderatthedesireddirectionhub.
4.PressandreleasetheMENUbuttonattheStandardDisplay;selectSpotAlignandstartthe
function using button 4 (fan beam will be activated).
Note:SpotAligncanalsobestartedthroughthepipeusingtheRC603viainfrared.
Note:ThedisplayfallsbacktothestandarddisplaywhileaSpotFindersymbolisashing.
TheplumbbeamwillbeautomaticallyalignedtothecenteroftheSF601.
5.Afteralingmentiscomplete(all4redLEDsattheSF601areon),theplumbbeamwillmoveverticallytothe
previousdialedinZ-axisgradevalue.
Note:AutomaticSpotAligncanbeexitedanytimebypressingandreleasingbutton3(ESC).