9 Default Settings
80 Trimble R7/R8 GPS Receiver User Guide
Trimble R7 GPS Receiver Operation
All Trimble R7 receiver settings are stored in application files. The
default application file, default.cfg, is stored permanently in the
receiver, and contains the factory default settings for the Trimble R7
receiver. Whenever the receiver is reset to its factory defaults, the
current settings (stored in the current application file, current.cfg) are
reset to the values in the default application file.
You cannot modify the default application file. however, if there is a
power up application file (power_up.cfg) in the receiver, the settings in
this file can be applied immediately after the default application file,
overriding the factory defaults.
For more information, see Application Files, page 53.
9.1 Default Settings
Table 9.1 shows the default settings for the Trimble R7 receiver, as
defined in the default application file.
Table 9.1 Default settings
Function Factory Default
SV Enable All SVs enabled
General Controls: Elevation mask 13°
PDOP mask 7
RTK positioning mode Low Latency
Motion Kinematic
Power Output 3 Disabled
1PPS time tags Off
ASCII time tags Off
Serial Port 1: Baud rate 38400
Format 8-None-1
Flow control None