Trimble R7/R8 GPS Receiver User Guide 55
Configuration 5
Trimble R7 GPS Receiver Operation
When you turn off the receiver then turn it on again, all the settings
from the current application file are applied, so you do not lose any
changes that you have made. The only exceptions are the following
logging parameters:
Logging rate
Position rate
Elevation mask
These parameters are always reset to the factory default values
whenever the receiver is switched off.
Power Up application file
the power up application file (power_up.cfg) is optional. if a power up
file is present, its settings are applied whenever the receiver is turned
on.
In this file, you can specify that the receiver is reset to defaults before
the power up settings are applied. This ensures that restarting the
receiver always results in the same configuration. This method is useful
for defining “default” settings for the receiver that differ from those in
the default file, which cannot be changed.
Alternatively, you can specify that the power up settings are applied
immediately after the current application file’s settings have been
applied. Restarting the receiver results in a configuration that uses your
default settings for the options you define in the power up file, but the
current settings for all other options.
By default, there is no power_up application file on the receiver. To use
a power up application file, you must create and save a power_up
application file in the GPS Configurator software. If you save this file to
disk, the file is called power_up.cfg. the extension .cfg is used by
convention to identify application files on the office computer. when
you transfer this file to the receiver, the file is saved on the receiver as
power_up, and becomes the new power up file.