User's Manual

Rev 2 Feb.13 Proprietary and Confidential - Contents subject to change 9
2
2: Power
Power supply
The host provides power to the EM7355 through multiple power and
ground pins. The host must provide safe and continuous power (via
battery or a regulated power supply) at all times; the module does not
have an independent power supply, or protection circuits to guard
against electrical issues.
For detailed pinout and voltage / current requirements of this module,
se
e the AirPrime EM7355 Product Technical Specification &
Customer Design Guidelines.
Module power states
The module has five power states, as described in Ta bl e 2 - 1 .
Table 2-1: Module power states
State Details
Host is powered
Module is powered
USB interface active
RF enabled
Normal
(Default
state)
Module is active
Default state. Occurs when VCC is first applied, Full_Card_Power_Off# is
deasserted (pulled high), and W_DISABLE#1 is deasserted
Module is capable of placing / receiving calls, or establishing data connections on the
wireless network
Current consumption is affected by several factors, including:
Radio band being used
Transmit power
Receive gain settings
Data rate
Low power
(‘Airplane
mode’)
Module is active
Module enters this state:
Under host interface control:
· Host issues AT+CFUN=0 ([1] AT Command Set for User Equipment (UE)
(Release 6) (Doc# 3GPP TS 27.007))), or
· Host asserts W_DISABLE#1, after AT!PCOFFEN=0 has been issued.
Automatically, when critical temperature or voltage trigger limits have been
reached))