User's Manual
Spectrum Research
& Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A06033011
Report No.: FCCA06033011
Page:
7 of 20
Date: May 12, 2006
FCC ID: TV2EFOBI
5.2 TEST EQUIPMENT
The following test equipment was used during the radiated emission test :
EQUIPMENT/
FACILITIES
SPECIFICATIONS MANUFACTURER
MODEL#/
SERIAL#
DUE DATE OF CAL. &
CAL. CENTER
EMI TEST
RECEIVER
9 kHz TO
2750 MHz
ROHDE &
SCHWARZ
ESCS30/
836858/008
AUG. 2006
ETC
BI-LOG
ANTENNA
25 MHz TO
2 GHz
EMCO
3142/
9701-1124
APR. 2007
SRT
PRE-AMPLIFIER
1GHz-26.5GHz
Gain:30dB(typ.)
HP
8449B/
3008A01019
DEC. 2006
ETC
SPECTRUM 9KHz TO 26.5GHz HP
8953E/
3710A03220
MAY 2006
ETC
HORN ANTENNA 1GHz TO 18GHz EMCO
3115/
9602-4681
NOV. 2006
ETC
OATS
3 – 10 M
MEASUREMENT
SRT SRT-1
APR. 2007
SRT
1. The calibration interval of the above test equipment is one year and the calibrations are traceable
to NML/ROC and NIST/USA.
2. The Open Area Test Site (SRT-1) is registered by FCC with No. 90957 and VCCI with No. R-1081.