User's Manual
Spectrum Research
& Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A06033011
Report No.: FCCA06033011
Page:
6 of 20
Date: May 12, 2006
FCC ID: TV2EFOBI
5. RADIATED EMISSION TEST
5.1 RADIATED EMISSION LIMIT
FCC part15C 15.209 limits of radiated emission measurement for frequency below
1000 MHz
FREQUENCY (MHz) DISTANCE (m) FIELS STRENGTH (dBµV/m)
30 - 88 3 40.0
88 - 216 3 43.5
216 - 960 3 46.0
ABOVE 960 3 54.0
FCC part15C 15.231(b) limit of fundamental and spurious emissions measurement.
FREQUENCY (MHz)
Field Strength of
Fundamental
(microvolts/meter)
Field Strength of Spurious
Emissions
(microvolts/meter)
40.66-40.70 2250 225
70-130 1250 125
130-174 1250 to 3750 (NOTE 5) 125 to 375 (NOTE 7)
174-260 3750 375 (NOTE 7)
260-470 3750 to 12500 (NOTE 6) 375 to 1250
Above 470 12500 1250
NOTE:
1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBµV/m) = 20 log Emission level (µV/m).
3.In the emission tables above, the tighter limit applies at the band edges.
4. Distance refers to the distance between measuring nstrument,
antenna, and the closest point of any part of the device or system.
5. Limit = 20log(56.81818(F) - 6136.3636) ; F : Fundamental Frequency (MHz)
6. Limit = 20log(41.667 x F – 7083.3333) ; F : Fundamental Frequency (MHz)
7. Limit = The Limit of Fundamental Frequency – 20dB
8. The maximum permitted unwanted emission level is 20 dB below the maximum permitted
fundamental level.