TEST REPORT
Reference No.: A06033011
Report No.: FCCA06033011
Page:
16 of 20
Date: May 12, 2006
FCC ID: TV2EFOBI
8. RELEASE OR OPERATING TIME
8.1 RELEASE TIME OR OPERATING LIMIT
1. A manually operated transmitter shall employ a switch that will automatically
deactivate the transmitter within not more than 5 seconds of being released.
2. A transmitter activated automatically shall cease transmission within 5 seconds after
activation.
3). Periodic transmissions at regular predetermined intervals are not permitted. However,
polling or supervision transmissions to determine system integrity of transmitters used in
security or safety applications are allowed if the periodic rate of transmission does not
exceed one transmission of not more than one second duration per hour for each
transmitter.
4. Intentional radiators, which are employed for radio control purposes during
emergencies involving fire, security, and safety of life, when activated to signal an alarm,
may operate during the pungency of the alarm condition.
8.2 TEST EQUIPMENT
The following test equipment was used during the radiated emission test :
EQUIPMENT/
FACILITIES
SPECIFICATIONS MANUFACTURER
MODEL#/
SERIAL#
DUE DATE OF CAL. &
CAL. CENTER
OSCILLOSCOPE
500MHz HP
54616B/
US39150351
APR. 2007
ETC
NOTE:
1. The calibration interval of the above test equipment is one year and the calibrations are traceable
to NML/ROC and NIST/USA.
8.3 TEST SET-UP
EUT (TX)
Oscilloscope
LOOP
ANT. PROBE