User's Manual

Spectrum Research
& Testing Lab., Inc.
No. 101-10, Ling 8,
Shan-Tong Li, Chung-Li
City, Taoyuan, Taiwan,
R.O.C.
TEST REPORT
Reference No.: A06033011
Report No.: FCCA06033011
Page:
10 of 20
Date: May 12, 2006
FCC ID: TV2EFOBI
RX
Frequency
(MHz)
Correct
Factor
(dB)
Antenna
Factor
(dB/m)
Polarization
Reading
(dBµV)
Peak/QP
Emission
Level
(dBµV/m)
Peak/QP
Limit
(dBµV/m)
Peak/QP
Margin
(dB)
Peak/QP
AZ
(°)
EL
(m)
152.2550 2.17 9.24 H 6.0 17.4 43.5 -26.1 268.9 1.4
300.1000 3.02 13.70 H 3.9 20.6 46.0 -25.4 130.2 1.2
502.3050 4.13 16.13 H 3.8 24.1 46.0 -21.9 98.2 1.2
601.0850 4.60 17.44 H 8.5 30.5 46.0 -15.5 129.6 1.1
802.4300 5.34 21.91 H 2.3 29.6 46.0 -16.4 78.3 1.1
932.5900 5.86 22.85 H 2.4 31.1 46.0 -14.9 220.6 1.2
167.0350 2.28 10.12 V 4.5 16.9 43.5 -26.6 221.1 1.3
401.3000 3.61 15.90 V 3.6 23.1 46.0 -22.9 296.3 1.2
428.3400 3.75 15.96 V 3.6 23.3 46.0 -22.7 88.7 1.1
649.1370 4.76 19.16 V 3.5 27.4 46.0 -18.6 20.3 1.1
732.9250 5.13 21.29 V 2.9 29.3 46.0 -16.7 117.2 1.0
840.9600 5.53 22.14 V 2.0 29.7 46.0 -16.3 89.5 1.0
NOTE :
1. Measurement uncertainty is +-/2dB.
2. "*":
Measurement value was too low to be detected.
3. Emissiom Level = Reading Value + Ant. Factor + Cable Loss.
4. The field strength of other emission frequencies were very low against the limit.
5.The emission level is lower than equipment ‘s noise.
6. Above 1GHz and up to 4.5GHz, the noise is very small.