Installation Guide for SecureMesh
®
WAN Extender 2 - PL-0072A
Note: For the surge suppressor to work properly, there must
be a low impedance path from the surge suppressor network
to earth ground.
In the case of a wooden or insulated mounting structure, a 10
AWG or larger ground wire needs to be added from the
grounding clamp, which forms the common ground node, to
earth ground. Consult with a professional engineer if you are
unsure about the grounding path.
If the PSE is connected to the XTEN-2000 with a long cable
run and/or is inside a building, Trilliant recommends adding a
second Ethernet surge suppressor outside the building at the
ingress point.