Installation Guide for SecureMesh
®
WAN Extender 2 - PL-0072A
Note: Always review the associated datasheet to ensure it complies
with the necessary installation and operational temperature ranges,
bend radius, and safety requirements needed for installation.
The maximum Ethernet cable length between the XTEN-2000 and the associated PSE
is 328 ft (100 m).
Trilliant recommends that a surge suppressor is installed between the PSE and the
XTEN-2000. The surge suppressor should be mounted adjacent to the XTEN-2000 so
that the cable length can be kept short, for example < 6 feet/1.8 m. Refer to Chapter 3
for additional information.
Cables without UV protection are acceptable, but should be installed inside a conduit
to limit the exposure to sunlight and moisture.
Recommended non-UV Cat6 and Cat6a cables:
l Comtran, COM-Link series (model number 35930 (blue)/3593 (gray))
l trueCable (model number 6ESCMPBLU (blue))
Kits and accessories
The following table includes parts and model numbers for kits and accessories.
Table 2: Parts and model numbers
Parts Model Number
Vertical pole mounting bracket DK-0029A
Mounting pole HM-0242A
Adjustable leveling bracket HM-0288A
Ethernet surge suppressor CMJ8-PoE-A-C5E (Citel)