Electrical specifications
Min.
Typ.
Max.
Voltage
4.0
4.5
5.0
Current
1. 2A
Physical, & Environmental
Mounting method
LGA (Land Grid Array)
Dimensions (L x W x H)
29.8 x 35.3 x 4.4 mm
Operating temperature
-40 °C to +85 °C
Humidity
5 to 95% non-condensing
Compliance
Radio emissions
•
FCC Part 15 Class B
•
ISED ICES-003 Class B
•
EN 55032, EN 55035
•
EN 300 489-1, EN 300 489-17
Unlicensed radio operation
•
FCC Part 15.212, 15.247
•
ISED RSS-Gen, RSS-247
•
EN 300 328
•
Others worldwide
Human Exposure
•
FCC Part 2.1091, 2.1093
•
RSS-102
•
EN 62209-2