User's Manual

SkyGateway/SkyExtender Installation And Configuration Guide
2-12 September 2004
Checking LEDs
Once power is on, the unit begins the boot process. The Link LED is green
and the Activity LED is yellow.
The LEDs operate as follows:
State-Based Blinking:
- Slow blink = 4 Blinks per second;
- Fast blink = 16 Blinks per second.
RSSI Based Blinking:
- RSSI = 0 blink/2Sec
- 0<RSSI<=10 blink/2Sec
- 10<RSSI<=20 blink/2Sec
- 20<RSSI 16 blink/2Sec
NOTE:If anything fails, refer to Chapter 3, Troubleshooting.
SkyExtender
Installation
SkyExtender installation involves the following steps:
Installing the Ethernet cable.
Installing the cover.
Table 2-3 : LED States
Process Link LED Activity LED
During Boot Slow Blink Slow Blink
Staggered
Boot Failed LED Off LED On
Image Inititalizing Slow Blink Slow Blink
Syncronous
Initialization Failure Initialization Failure Fast Blink
Syncronous
Initial Success but no auth LED On LED Off
SkyGateWay connected LED On LED On