Installation Guide
SecureMesh
TM
Extender Installation Guide
Trilliant Incorporated page 6 of 21
PREPARING FOR INSTALLATION
Required Equipment
A power supply, typically one of the power supplies listed as an Extender accessory. For all outdoor
installations, the PSU-1024-33A SecureMesh Power Service Unit is recommended unless an
Uninterruptible Power Supply is available.
A CAT5e, UV-protected, Shielded-Twisted Pair (STP) Ethernet cable with ground wire for connecting
the Extender’s Surge Protector to the PoE power supply.
One of the accessory mounting brackets listed above or provide a mounting bracket including a vertical
pole with a 1.25‖ to 2‖ diameter that is a minimum of 18‖ from any structure to the side of the Extender.
The vertical pole must extend a minimum of 5‖ above a horizontal surface of the bracket.
A 10 AWG (or larger) ground wire of sufficient length to connect the Extender to the primary grounding
point of the utility structure to which the Extender will be mounted.
A magnetic level to ensure the Extender is plumb.
Self-fusing rubber insulation and sealing tape such as Scotch
®
130C or 2228 Rubber Mastic Tape
Optional Equipment
The following equipment is required to support optional manual provisioning of the Extender:
A computer connected to the same Ethernet network as the SecureMesh Extender. The Extender’s
default IP address is 192.168.0.2.
A CAT5e, Ethernet cable for connecting the Extender’s Surge Protector to the PoE power supply.
Installation Location
In general, a SecureMesh Extender should be installed in a location that will not obstruct the radio signals to
and from the SecureMesh Extender. The SecureMesh Extender should be installed in a location that meets all
of the following guidelines:
Installation and wiring of the SecureMesh Extender must conform to all local electrical codes and
ordinances.
The installation location must be either owned by the utility or the utility must have access rights to the
location.
The installation location must be able to provide adequate power. Note that the 24V Power Service
Unit requires 90-265 VAC 50/60 Hz power.
The Extender enclosure must be mounted at least 18 feet (5.5 meters) above ground level, although
radio performance and coverage will generally improve as the mounting height is increased.