User Guide

Base Station Configuration
Access Point Deployment Guide 72
NOTICE: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its subsidiaries, affiliates, and/or licensors. This
document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant. The contents may not be used or disclosed
without the express written consent of Trilliant.
Base Station Option
Description
Applications
Required Hardware
Additional Items Required
TRN-1021 Base
Station
Outdoor base station
Solar powered
Access Point is located
outdoors
3G modems and backup
batteries are located
inside the equipment
cabinet
Outdoor locations without
power requiring 3G modem
backhaul.
For example:
Transmission towers
Sites without power
Access Point
Outdoor equipment cabinet powered by
solar system and contains:
o 3G modem
o Two integrated 3G modem antennas
o Antenna surge suppressor
o Two backup batteries
o Alarm monitor
GPS antenna
9 dBi AP antenna
Pipe mounting hardware for a 4-inch OD
pipe
All cables (with the exception of the cable
for the AP antenna)
Customer-supplied 3G
Digi modem (U805)
Site-specific cable for the
AP antenna
Customer-supplied 4-inch
OD pipe for mounting
equipment
Site-specific installation
hardware
TRN-1031 Base
Station
Indoor rack-mounted
base station
Contains a 19-inch rack
3RU shelf
AP is mounted on the
shelf
Powered by either
120/240 VAC or 48
VDC
Indoor rack mount
environment with access to
power and corporate IP
network.
For example:
Communication site shelters
IT equipment rooms
Substation equipment rooms
Access Point
A 19-inch rack 3RU shelf including:
o 120/240 VAC power supply
o 48 VDC terminal strip/cable
Antenna surge suppressor
GPS antenna
9 dBi AP antenna
Site-specific cables for the
AP antenna and the GPS
antenna
Site-specific installation
hardware