User's Manual

Table Of Contents
51
Seeker & Seeker MCA III Operation Manual
Appendix
Chapter 8
General Specications
FrequencyRange
Settable using Seeker Setup Software, in 6.25 kHz steps.
LowBand: 109.25 to 110.50 MHz
HighBand: 118.50 to 147.25 MHz
Older Seekers do not include the low band frequency from 109.25
to 110.5 MHz. Seekers that are low band frequency compatible
will have a label on the back of the device indicating “LOW BAND
ENABLED”.
Frequency
Presets
10 user-set operating frequencies, selectable on front panel.
Selections are loaded into the detector using Seeker Setup software.
LevelRange
2 to 2000 mV/M. Can freeze current numeric reading or hold peak
readings.
Numerical
Display
LCD readout of any detected leakage within sensitivity range.
AudibleTone
Tone is present if leakage amplitude exceeds squelch setting. Pitch
is proportional to strength of leak.
Leakage
Sampling&
RecordingRate
33 times/second sampling, 1 record/second continuous logging.
ChannelTag
Range
10 Hz to 23 Hz (Excluding 16 Hz)
Power Built-in Lithium-ion battery
OperationTime
MeasurementMode: Eight hours, typical
ChargeTime: Less than three hours for full-charge in the mobile
mount, six hours for charging using the mini-USB connection.
Dimensions 7.48 x 3.43 x 1.85 in (190 x 87 x 47 mm)
Weight 0.95 lbs (431 g)