User's Manual

Table Of Contents
40
Seeker & Seeker MCA III Operation Manual
3. ConrmtheSeekerisinMeasurementmode
The Antenna icon on the display should be blinking for the Measurement mode. If
necessary use the SELECT button to move to the Measurement mode.
4. Beginleakagetesting
Move the Seeker around the test area. If the detected leakage level exceeds the
squelch level (default 2 mV/m), the Seeker will alarm.
The frequency of the alarm tone will increase as the detected signal strength increases.
Continue to move the Seeker in the direction producing the highest tone frequency to
locate the source of the leak.
5. TurnOFFtheSeeker
When testing is complete, turn off the Seeker by holding down on the red on/off button.
This step is not required if the user leaves the Seeker in the Mobile Mount.