from the I.F. source modulator, should be labeled by the customer as the ā€œPrimary LS-16Pā€.
Any other Primary LS-16P output port may be used to drive Secondary LS-16P(s) input ports or SW-1 and SW-4
switches.
For example, in a typical headend of 46 channels you will need three (3) LS-16P(s). One LS-16P will serve as the
Primary and the two (2) remaining LS-16P(s) will serve as Secondaries. Total channel capacity will be twelve (14) ports
from the Primary LS-16P, with the remaining two (2) ports of the Primary feeding two (2) Secondary LS-16P(s). Two (2)
times sixteen (16), or thirty (32) ports from the Secondary LS-16P(s) added to the fourteen (14) ports leftover from the
Primary LS-16P totals 46 ports.
As shown in the following diagram, one (1) LS-16P will serve up to sixteen (16) remotely located SW-1 and/or SW-4
equipped modulators and processors and/or Secondary LS-16P(s). When installing the LS-16P, place in bays or racks
where their distribution coverage will be maximized. See the following diagrams.
Typical LS-16P Placement and Connection.
Bundled drop cable feeding I.F. switches
LS -16P