User's Manual
Table Of Contents
DRAFT
EASyCAP Encoder/Decoder - Manual
30
Encoder/Decoder Settings
Select the Edit button to change the encoder/decoder settings, and then adjust any of the
following settings:
Description - Enter the name that you wish to display for this encoder/decoder. This
name should be descriptive enough to be able to easily discern it within the EAS
Encoder List.
IP Address - Enter the IP address used to connect to the selected encoder/decoder.
Command Port - Enter the TCP command port used to communicate with the
selected encoder/decoder. The default value is 59911.
Audio Port - Enter the TCP port used to transfer audio from the Encoder/Decoder to
the encoder/decoder. The default value is 59919.
Password - Enter the password used to login to the configured Encoder/Decoder. This
should be a special CAP account added to the user accounts of the Encoder/Decoder,
and given EAS Alert and Ethernet permissions in the user account.
Call Sign - Enter the station identification that will be included in the alert text.
No EAN audio - When this box is selected the EAN audio stream will not be used,
Encoder/Decoders will receive EAN audio from a local audio input.
After making changes, select the Save button to save the encoder/decoder settings.