CONVERSION OF GAS 
Your cooker is designed to work with natural gas, 
and is convertible for use with propane or butane.
The LPG conversion kit is available from your 
Service Force Centre and must be fitted by a 
Registered engineer/ competent person. 
For changing the gas type it is necessary to: 
•  replace the nozzles (hob, oven and grill); 
•  adjust the minimum level (hob and oven); 
•  adjust the primary air (oven and grill); 
•  check the gas connection; 
 Stick the label supplied with the 
replacement nozzles (from the Service Force 
Centre) corresponding to the gas type utilized.
SPECIFICATION NOZZLES 
Table no.1 
(Cat : II
2H3+
) 
Cons 
Burner 
Normal 
power 
(kW) 
Simmer 
power 
(kW) 
By-
pass 
(mm) 
Gas Type 
Pressure 
(mbar) 
Nozzle 
diameter 
(mm) 
m
3
/h g/h 
RAPID 2.60 0.72 0.42 
Natural Gas 
Butane 
Propane 
20 
28-30 
37 
1.12 
0,86 
0,86 
0.248 
- 
- 
- 
189,05
185,68
SEMI-
RAPID 
2.00 0.43 0.32 
Natural Gas 
Butane 
Propane 
20 
28-30 
37 
0.96 
0,71 
0,71 
0.191 
- 
- 
- 
145,43
142,83
AUXILIARY 1.00 0.35 0.29 
Natural Gas 
Butane 
Propane 
20 
28-30 
37 
0.70 
0,50 
0,50 
0.093 - 
72,71 
71,41 
OVEN 3.20 1.00 0.46 
Natural Gas 
Butane 
Propane 
20 
28-30 
37 
1.30 
0,88 
0,88 
0.305 
- 
- 
- 
232,68
228,52
GRILL 2.50 -  - 
Natural Gas 
Butane 
Propane 
20 
28-30 
37 
1,15 
0,80 
0,80 
0,238 
- 
- 
- 
181,78
178,53