User manual
20
INSTALLATION 
Location of appliance 
The appliance must not be installed in a bed-
sitting room of volume less than 20m
3 
or in a 
bathroom or shower room. It is essential that the 
appliance is positioned as in the enclosed figure 
i.e. shelves, wall cabinets and cooker hoods 
must be fitted a minimum of 690mm directly 
above the hob and 400mm above the hob when 
fitted in line with the outside of the appliance. If 
the units are intended to be fitted adjacent to the 
appliance but less than 400mm above the hob, 
then a minimum space of 100mm must be 
maintained between the sides of the unit and 
the appliance (see fig). 
If fitted next to or between two base units a 
minimum space of 1mm must be left between 
each unit and the sides of the appliance. The 
levelling feet fitted to the appliance will 
achieve a nominal height to hob of 
900mm+10mm. 
The appliance must be installed in 
accordance with EN 1116-1995, regarding 
the depth of the superior furniture. 
690 
400 
min 600
max 400
min 570
690 
less than
400
100
C
2
1
3
4
5
6
7
8
G
C
2
1
3
4
5
6
7
8
G
 L.P.G. cookers or ovens MUST NOT 
be installed below ground level, i.e. in a 
basement, or aboard any boat, yacht or 
other vessel. 
The cooking appliance must be 
fitted with a stability chain firmly secured 
to the wall. 
Stability 
chain 
Stability 
hook 
Chain to be as 
short as 
practicable 
Firmly fix 
chain to rear 
of cooker 
Ventilation 
The room containing the cooker should have an 
air supply in accordance with B.S. 5440: Part 2: 
Current Editions. 
The following requirements for ventilation 
must be met. 
The cooker should not be installed in a bed 
sitting room with a volume of less than 20m
3
, if 
it is installed in a room of volume less 5m
3
 an 
air vent of effective area of 110cm
2
 is required; 
if it is installed in a room of volume between 
5m
3
 and 10m
3
, an air vent of effective area 
50cm
2
 is required, while if the volume exceeds 
11m
3 
no air vent is required. However, if the 
room has a door, which opens directly to the 
outside, no air vent is required even when the 
volume is between 5m
3
 and 11m
3
. 
If there are other fuels burning appliances in 
the same room, B.S. 5440: Part. 2: Current 
Editions should be consulted to determine 
the requisite air vent requirements.