User Manual
19
ELECTRICAL CONNECTIONS 
Any electrical work required to install 
this hob and the supply cable should be 
carried out by a qualified electrician or 
competent person, in accordance with the 
current regulations. 
THIS COOKER MUST BE EARTHED. 
The manufacturer declines any liability 
should these safety measures not be 
observed. 
Before any maintenance or cleaning can 
be carried out, you must DISCONNECT the 
cooker from the electricity supply. 
This cooker is designed to be connected to a 
230-240V AC, 50Hz electrical supply. 
To connect to the electricity supply, use cable  
type H05 RR-F. 
Before connection, make sure the electricity 
supply voltage is the same as that indicated on 
the rating plate. 
The cooker is supplied without supply cable. A 
flexible supply cable must be fitted, in 
accordance with the specification given in the 
relevant table no. 1. 
The electrical connection should be made using 
a double pole-isolating switch (cooker control 
switch) with at least 3mm contact separation in 
all poles. The cable must have conductors of 
sufficiently high cross-sectional area to prevent 
overheating or deterioration. 
The switch should be sited within 2m of the 
cooker and be easily accessible at all times. 
The switch must not interrupt the yellow-green 
earth wire. 
NOTE: The earth wire should be about 2 cm 
longer than the live and neutral wires. 
After installation and connecting, the cable must 
be placed so that it cannot at any point reach a 
temperature of more than 50°C above the ambient 
temperature. 
 If the supply cable is damaged, the 
manufacturer or its service agent or a 
similarly qualified person must replace it in 
order to avoid a hazard. 
Before connecting check that: 
•  The fuse and household electrical 
installation can carry the absorbed current of 
the appliance (see rating plate); 
•  The cooker connection outlet or the cooker 
control switch is easily accessible when the 
appliance is installed. 
How to proceed? 
•  Unscrew and remove the protective cover at 
the back of the appliance; 
•  Connect the power cable to the terminal 
block of the cooker according to the table 
no.1; 
•  Secure by means of cable clamp; 
•  Make sure that the connection to the 
terminal block is matching the supply 
system, see table no.1; 
•  Refit and screw the protective cover on the 
back of the appliance. 
Table no.1 
Connection type  Single phase (UK) 
Cable connection to the 
terminal block 
1 2  3 4 5
L1
N PE
Mains Voltage 
240 V 
Voltage of heating 
elements 
240 V 
Fuse capacity 
45 A 
Cable section 
3x6 mm
2 