User manual

4
Ignition HT Spark
Spark Generator Ispra Control's BF 50046 - 240V 0.6 YA T 120
Spark Gap Fixed
Rear Left Burner (semi rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Left Burner (rapid)
Heat Input 3.0 kW (10236 BTU/HR)
OVERALL DIMENSIONS
Width: 580 mm.
Depth: 510 mm.
Thickness: 30 mm.
Height: 72 mm.
Weight: 9 Kg.
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.
This appliance complies with the EEC Directive No 89/336, concerning suppression of radio electrical
interference.
Burner Dia. Tap By-pass Tap colour
1/100 mm
Auxiliary 28 Red/Red
Semi-rapid 32 Blue/Blue
Rapid 40 Black/Black
Aeration adjustement none
TECHNICAL DATA
CUT OUT DIMENSIONS
Width: 560 mm.
Depth: 480 mm.
BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 3.0 0.6 2.0 0.4 1.0 0.3
NOMINAL FLOW
RATE m
3
/h 0.286 57 0.190 38 0.095 28
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust.
NOMINAL THERMAL
POWER kW 2.8 0.6 2.0 0.4 1.0 0.3
NOMINAL FLOW
RATE g/h 202 43.5 144 29 72 21.5
NOZZLE REFERENCE 86 40 71 32 50 28
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Rear Right Burner (semi rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Right Burner (auxiliary)
Heat Input 1.0 kW (3412 BTU/HR)