Datasheet

TRIAX - your ultimate connection
Multiband Amplier TMB 100
| Technical Data
| Connection Diagram
TRIAX A/S | DK-8783 Hornsyld | www.triax.com 351066 1-2015 Misprints, errors and modifications reserved.
Number of inputs
5
Transmission ranges
Terrestrial frequency range UHF
Terrestrial frequency range B III
Terrestrial frequency range B I-FM
MHz
MHz
MHz
470...862*
174...240
47...108
Amplification
Input level max. B I-FM / B III / UHF
Gain B I-FM
Gain B III
Gain UHF
Noise Factor BI-FM / B III / UHF
Attenuator per input Bi-FM, B III
Global attenuator for UHF inputs
Output level max. VHF / UHF
(IM
3
- 60 dB)
dBµV
dB
dB
dB
dB
dB
dB
dBµV
90 / 80 / 95
32
48
55
9 / 5 / 7
0...20
0...20
120 / 117
TMB 100
Order No. 360223
Filter combination
UHF filter distribution UHF 1/UHF 2/
UHF 3
Width of filtering channels (1...7 ch.)
Filter selectivity @ + 16 MHz
Input return loss
Output return loss
MHz
dB
dB
dB
3 / 5 / 2
1 / 7 / 2
- / 8 / 2
3 / - / 7
1 / - / 9
- / - / 10
8...56
>14
>8
>8
Operating conditions
Power supply (50-60 Hz)
Power consumption at 230 VAC
Remote supply UHF 1, 2, 3
Input equipped with remote supply
Operating temperature
VAC
W
V/mA
°C
100...240
9...16
12 or 24/80
UHF 1, 2, 3
-5...+40
Mechanics
Input/output connectors
Dimensions (H x W x D)
mm
F-female
225 x 220 x 50
TMB 100
Best.-Nr. 360223
* LTE protection „on“: 470...790 MHz, ch. 21-60
Output
Programming
Menu