Datasheet
191
Triax taps - TLT series [outdoor]
Technical data TLT series of 5-1000 MHz outdoor 4-taps
TYPE
Part No.
TLT 423
80251
TLT 426
80252
TLT 429
80253
TLT 432
80254
TLT 435
80255
Frequency range MHz 5 - 1000 5 - 1000 5 - 1000 5 - 1000 5 - 1000
Inputs pcs 1 1 1 1 1
Outputs pcs
4 4 4 4 4
Insertion loss
5 - 40 MHz
40 - 470 MHz
470 - 750 MHz
750 - 862 MHz
dB
dB
dB
dB
< 0.8
< 1.3
< 2.0
< 2.0
< 0.8
< 1.3
< 2.0
< 2.0
< 0.8
< 1.3
< 2.0
< 2.0
< 0.8
< 1.3
< 2.0
< 2.0
< 0.8
< 1.3
< 2.0
< 2.0
Tap loss - output
5 - 40 MHz
40 - 470 MHz
470 - 750 MHz
750 - 862 MHz
dB
dB
dB
dB
23.0 (± 1.2)
23.0 (± 1.2)
23.0 (± 1.5)
23.0 (± 1.5)
26.0 (± 1.2)
26.0 (± 1.2)
26.0 (± 1.5)
26.0 (± 1.5)
29.0 (± 1.2)
29.0 (± 1.2)
29.0 (± 1.5)
29.0 (± 1.5)
32.0 (± 1.2)
32.0 (± 1.2)
32.0 (± 1.5)
32.0 (± 1.5)
35.0 (± 1.2)
35.0 (± 1.2)
35.0 (± 1.5)
35.0 (± 1.5)
Isolation - out/tap
5 - 40 MHz
40 - 470 MHz
470 - 750 MHz
750 - 862 MHz
dB
dB
dB
dB
> 27.0
> 27.0
> 27.0
> 27.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
Isolation - tap/tap
5 - 40 MHz
40 - 470 MHz
470 - 750 MHz
750 - 862 MHz
dB
dB
dB
dB
> 28.0
> 28.0
> 28.0
> 28.0
> 27.0
> 27.0
> 27.0
> 27.0
> 29.0
> 29.0
> 29.0
> 29.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
Return loss (out)
5 - 40 MHz
40 - 470 MHz
470 - 750 MHz
750 - 862 MHz
dB
dB
dB
dB
> 18.0
> 19.0
> 19.0
> 19.0
> 18.0
> 22.0
> 22.0
> 22.0
> 18.0
> 22.0
> 22.0
> 22.0
> 18.0
> 22.0
> 22.0
> 22.0
> 18.0
> 22.0
> 22.0
> 22.0
Shielding efficiency VHF/UHF dB ≥ 100.0 ≥ 100.0 ≥ 100.0 ≥ 100.0 ≥ 100.0
Hum modulation @ 10 A dB ≥ 66 ≥ 66 ≥ 66 ≥ 66 ≥ 66
Power pass connection In/out In/out In/out In/out In/out
DC-throughpass A/VAC 10/60 10/60 10/60 10/60 10/60
Connectors F-connector F-connector F-connector F-connector F-connector
Certification
Impedance Ohm 75 75 75 75 75
Weight kg
Dimensions (h x d x w) mm
125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145