Manual

23
Do not use automotive, ethylene glycol or
petroleum-based antifreeze. Do not use
any undiluted antifreeze. This can cause
severe personal injury, death or substantial
property damage.
Water from opened drain valves, unions
and other connections may be extremely
hot. To avoid severe personal injury, death
or substantial property damage:
- Tighten all drain hose connections.
- Direct hot water away from all persons.
Draining Inner (Domestic Water) Tank
(See Domestic Piping Fig. 1 page 8)
1. Disconnect  snap  set  wiring  connection  at
water heater. 
- If  outer  (boiler  water)  tank  pressure  is
greater  than  15  psig,  relieve  boiler  pres-
sure and close isolation valves before pro-
ceeding.
2. Close system supply isolation valve.
3. Connect a hose to domestic water drain valve
at  cold  water  inlet.  Hose  should  extend  to
drain  at  floor  level  to  allow  siphoning  of
domestic water tank.
4. Open hot water faucet at highest point above
heater.
5. Open  domestic  water  drain  valve  to  start
siphoning.
6. When  draining  is complete, close hot  water
faucet and domestic water drain valve.
Draining Outer (Boiler Water) Tank
1. Disconnect snap set wiring  connection at
water.
2. Close boiler  water  isolation valves between
boiler and water heater.
3. Connect  hose  to boiler water drain  valve  at
water heater.  Open and drain water to a safe
place.
4. To speed draining procedure, loosen air vent
on top of tank.
5. When draining is complete, close drain valve
and retighten air vent.
WARNING
WARNING
Water Heater Maintenance