Manual

Installation - Wiring
14
Wiring Requirements
Electrical shock hazard can cause severe
personal injury, death or substantial prop-
erty damage. Disconnect power before
installing and/or servicing.
1. All  wiring  must  be  a  minimum  of  18  gauge
and installed in accordance with:
U.S.A. - National Electrical Code and any
other national, state or  local  code  require-
ments having jurisdiction.
Canada - C.S.A. C22.1 Canadian Electrical
Code Part 1 and any other national, provin-
cial  and  local  code  requirements  having
jurisdiction.
2. If original wire supplied with appliance must
be replaced, Type 90ºC or its equivalent must
be used.
3. Refer to control component instructions
packed with boiler for application information.
4. An optional service switch may be installed in
water  heater  electrical  circuit.  This  switch
would  only shut  off  the  water heater,  not  the
home  heating  system.  Do not  shut off water
heater if there is a chance of freezing.
5. All  electrical  contacts  shown  do  not  have
power  applied  -  off  the  shelf  condition.  See
pages 15 thru 18.
Circulators
Priority relay must be sized for total amp draw
of all circulators.
Zone Valves
Transformer must be sized for maximum load
of all zone valves.
Snap Set Connection
For easy wiring between water heater thermo-
stat and boiler controls see Installation Wiring
section pages 15 through 18.
Make sure snap set is firmly snapped together
after wiring.
WARNING
Snap Set Wiring
Connect to
outer 2 terminals