Install Instructions
PRESTIGE TriMax Control
and/or Display Module Replacement
4
6. Remove all (8) Molex wiring connectors from
the Control Module. Support Trimax Control
Module with one hand while removing individ-
ual Molex connectors. Press tabs on Molex
plugs for quick release. See Fig. 5.
7. Remove the 2 screws securing the Control
Module into the enclosure and remove the
Control Module. Do not discard the Trimax
Control Module. See Fig. 6.
Go to step 15 if one only wants to remove the
Trimax Control Module. Proceed to step 8 if the
Trimax Display Module must also be removed.
Removal of Trimax Display Module
The Trimax Control Module must always be
removed prior to removing the Trimax Display
Module.
8. Remove Molex connectors 1 thru 3 from the
Display Module as shown in Fig. 7.
9. Remove 6 screws securing the Trimax Display
Module to the enclosure.
10. Remove Molex connectors 4 thru 6 from the
display module as shown in Fig. 7.
11. Carefully remove the Trimax Display Module.
Installation of Trimax Display Module
12. Reconnect Molex connectors 4 thru 6 to the
new display module as shown in Fig. 7.
Connectors are designed to fit only into its
respective mating connector.
NOTICE
NOTICE
Retaining Tabs
Fig. 4: Control Box Assembly
1
2
6
5
43
7
8
Fig. 5: Control Module Molex Connections
Mounting
screw
l
ocation
Mounting
screw
location
Fig. 6. Control Module Mounting
Prestige_TriMax_Control_Display_Module_DCR639 1/14/14 9:45 AM Page 4