PVC/CPVC Sidewall Vent Termination Kit Instructions
PVC/CPVC Low Profile Sidewall
Vent Termination Kit
1
Kit Part Number:
PSVTERM03
2 Inch PVC/CPVC Vent Sidewall Termination
PSVTERM04
3 Inch PVC/CPVC Vent Sidewall Termination
PSVTERM05
4 Inch PVC/CPVC Vent Sidewall Termination
Recommended tools:
• Phillips Screwdriver
• Core Drill or Hole Saw
Failure to follow instructions below can result
in severe personal injury or damage if ignored.
• Instructions are for a qualified installer/ser-
vice technician.
• Read all instructions before proceeding.
• Follow instructions in proper order.
The sidewall vent termination is certified to
ULC S636 standard.
This vent termination must be installed in
accordance with all applicable local, state,
national and provincial codes, ordinances,
regulations and laws.
WARNING
NOTICE
NOTICE
Indicates a potentially hazardous situation
which, if ignored, can result in serious
injury or substantial property damage.
Indicates special instructions on installa-
tion, operation or maintenance, which are
important to equipment but not related to
personal injury hazards.
WARNING
NOTICE
Termination
plate
Wall Plate
Fig. 1: PVC/CPVC Sidewall Vent Termination