User Guide

29
CHAPTER 5
CHAPTER 5 - INSTINCT COMBI UNITS - DOMESTIC PIPING
5.3. Water Hammer
Dishwashers, clothes washers and fast-closing positive
shut-o valves incorporated in the system all contrib-
ute to creating water shock. Install a water hammer ar-
rester to prevent damage to pipes and appliances. See
device manufacturers instructions for application and
installation.
Water hammering within the domestic piping
system can cause premature failure of the do-
mestic circuit of the boiler. This type of failure is
NOT covered under warranty.
NOTICE
Fig. 16 - INSTINCT Combi - Hydro-block Flow Diagram
5.4. Vacuum Breaker
Installing a vacuum breaker on the domestic cold wa-
ter inlet will prevent damage to the domestic circuit if
a negative pressure is developed in the domestic sup-
ply line. See manufacturers instructions for application
and installation of the vacuum breaker.
5.5. Hydro-Block
The domestic circuit provides domestic hot water
through a hydro-block. It is made of a plate-to-plate
heat exchanger and connections to the primary and
domestic piping. Water heated in the primary circuit
(central heating) ows into the plate-to-plate heat ex-
changer, which in turn heats the domestic water ow-
ing through it in its own circuit. Refer to Fig. 16 below
for ow diagram.
CH SUPPLY
CH SUPPLY
CH RETURN
CH RETURN
to PUMP
DHW SUPPLY
DHW INLET
Flow Sensor
DHW Temperature Sesnor
1
1 3/4”
3/4”
1
1
Stepper motor + cartridge
Plate-to-plate heat exchanger