CTRLMax Manual
51
CHAPTER 6
CHAPTER 6 - MANUAL OPERATION
Manual Operation
FAN
CH1
CH2
DHW
Released
O
O
O
Manual Operation
FAN
CH1
CH2
DHW
Released
O
O
O
Manual Operation
FAN
CH1
CH2
DHW
Released
O
O
O
Manual Operation
Manual Operation
FAN
CH1
CH2
DHW
Released
O
O
O
To ensure the operation of the heating system,
make sure to switch on one of the pumps.
NOTICE
FAN - Actuate the OK key while the FAN icon is highlighted to
manually re the burner and power the CH (1) circulator.
Adjust the ring rate from 0% (Low Fire) to 100% (High Fire) using
the LEFT and RIGHT keys.
Hold down the LEFT or RIGHT keys to rapidly increase or de-
crease the ring rate.
Actuate the OK key again while the FAN icon is highlighted to
shutdown the burner when nished.
CH1 - Actuate the OK key while the CH1 icon is highlighted
to manually power the CH 1 circulator(s) as in CH demand.
Actuate the OK key again while the CH1 icon is highlighted
to shutdown the CH1 circulator(s).
The auxiliary Appliance circulator is also powered
when the CH1 circulator is manually enabled.
DHW - Actuate the OK key while the DHW icon is highlighted
to manually power the DHW circulator(s) as in DHW demand.
Actuate the OK key again while the DHW icon is highlight-
ed to shutdown the DHW circulator(s).
The auxiliary Appliance circulator is also pow-
ered when the DHW circulator is manually en-
abled.
CH2 - Actuate the OK key while the CH2 icon is highlighted
to manually power the CH2 circulator(s) as in CH demand.
Actuate the OK key again while the CH2 icon is highlighted
to shutdown the CH2 circulator(s).
Installer Code