CTRLMax Manual

24
CHAPTER 5
CHAPTER 5 - BOILER SETTINGS
Boiler Settings
Boiler Settings
Model Prstige Solo
Lockout Temp. 210°F [99°C]
Modbus Address 0=BCST
Pump settings
Ignition Level 3500rpm
Mix zone high limit 45°C
Pump Settings
Current Pump Cong Modied
Preset Pump Cong
Flexible Pump Cong
Pump PWM minimum 40%
Pump Settings
Current Pump Cong Modied
Preset Pump Cong
Flexible Pump Cong
Pump PWM minimum 40%
Pump Settings
Current Pump Cong Modied
Preset Pump Cong
Flexible Pump Cong
Pump PWM minimum 40%
Flexible Pump Cong
Flex. Relay 1 (CH)
Flex. Relay 2 (DHW)
Flex. Relay 3 (P3)
Flex. Relay 4 (ERR)
Flex. Relay 5 (Flame)
Flex. Relay 6 (P4)
Preset Pump Cong
Cong 1
Cong 2
Cong 3
Cong 4
Cong 5
Cong 6
The Pump Settings menu allows to choose the right pump
conguration to the chosen hydraulic conguration.
The Current Pump Cong indicates which conguration is
currently selected for the appliance.
Two appliance conguration modes are available : a preset
conguration mode and a exible conguration mode.
Scroll through the settings using the UP or DOWN keys,
then validate the selection with the OK key.
In the Preset Pump Cong. (preferred selection) you can
choose from a number of preset pump congurations.
Only the congurations usable with a certain model/type
of appliance will appear in the list. Each conguration is
detailed through one or several hydraulic diagrams, a table
indicating the electrical connections and a list of the pa-
rameters to be dened in CTRLMax.
Scroll through the settings using the UP or DOWN keys,
then validate the selection with the OK key.
Although the menu is available in the
INSTINCT units, do not use the Preset Pump
Config Function, unless specified in Fig. 3 on
page 29 thru Fig. 16 on page 42 .
NOTICE
The Flexible Pump Cong. menu allows to customize the
pump conguration to the chosen hydraulic conguration.
Only select this option when the preset congurations do
not oer you a solution. In this menu you have to choose
per relay for which heat demand / function it will be activat-
ed. The relays are allocated as follows by default (see picture
below for physical location on the optional terminal blocks) :
Flex. Relay 1 ..............CH
Flex. Relay 2 ..............DHW
Flex. Relay 3 ..............P3
Flex. Relay 4 ..............ERR
Flex. Relay 5 ..............FL
Flex. Relay 6 ..............P4
Scroll through the settings using the UP or DOWN keys,
then validate the selection with the OK key.
The use of the Flexible Pump Config. menu is not
possible for the Solo/Excellence (3 way valve).
Flex Relays 3, 4 and 6 are not available in INSTINCT
units.
NOTICE
CTRLMax_w Instinct_UK version_222171_A01.indd 24 18/07/2019 18:38