CTRLMax Manual
23
CHAPTER 5
CHAPTER 5 - BOILER SETTINGS
The Boiler Settings menu contains settings related to ap-
pliance operation. Each line contains an appliance setting
followed by its current value.
The Model menu indicates the model and possibly type
of appliance for which the system is set up. Five dierent
models can be displayed: PRESTIGE Solo, PRESTIGE 3WV
(for Prestige Excellence), HEATMASTER, INSTINCT Solo AND
INSTINCT Combi.
CH & DHW Settings
The Lockout Temp. setting allows testing of the overheat
thermostat function at a reduced temperature. It tempo-
rarily decreases the overheat temperature of the appliance
to 102°F which allows a safe demonstration of the function.
When setting the value to 102°F, a High temperature lock-
out (E3) will occur when the boiler reaches 102°F.
Scroll through the settings using the UP or DOWN keys,
then validate the selection with the OK key.
Default: 210°F
This parameter sets the Modbus address of the appliance
in a Modbus based communication system.
Adjust the Modbus Address value using the LEFT or RIGHT
keys, then store the setting with the OK key.
Default: 0=BCST
Boiler Settings
Boiler Settings
Model Prestige Solo
Lockout Temp. 210°F [99°C]
Modbus Address 0=BCST
Pump settings
Ignition Level 3500rpm
Mix zone high limit 114°F
Boiler Settings
Model Prestige Solo
Lockout Temp. 210°F [99°C]
Modbus Address 0=BCST
Pump settings
Ignition Level 3500rpm
Mix zone high limit 114°F
Lockout Temp.
102°F [39°C]
210°F [99°C]
Boiler Settings
Model Prestige Solo
Lockout Temp. 210°F [99°C]
Modbus Address 0=BCST
Pump settings
Ignition Level 3500rpm
Mix zone high limit 114°F
Modbus Address
0=BCST
0=BCST 247
Navigate on the screen using the UP, DOWN, LEFT and RIGHT keys,
then the validate a selection with the OK key. To increase/decrease
values, use the UP and DOWN or LEFT and RIGHT keys, according to
the situation and validate with OK.
NOTICE
Installer Code