CTRLMax Manual

19
CHAPTER 4
CHAPTER 4 - DHW SETTINGS (INSTINCT COMBI ONLY)
DHW Operation prompts to enter the xed setpoint tem-
perature during a domestic hot water call.
Select Enabled or Disabled using the UP or DOWN keys, then
store the setting with the OK key.
Enabled - The appliance will respond to a domestic hot
water call.
Disabled - The appliance will not respond to a domestic
hot water call. The domestic hot water oper-
ation disabled icon ( )is displayed on the
home screen when domestic hot water oper-
ation has been disabled.
DHW Operation default: Enabled
CH & DHW Settings
DHW Setting
DHW Setting
DHW Operation Enabled
DHW Setpoint 140°F
DHW on Dierential 18°F
Warmstart Temperature 126°F
Warmstart Hysteresis 30°F
DHW Post Pump Time 2 min
DHW Operation
Disabled
Enabled
The DHW Setting menu contains settings related to domes-
tic hot water operation. Each line contains a DHW Setting
followed by its current value. Six DHW Settings are displayed
on the screen at one time.
Navigate on the screen using the UP, DOWN, LEFT and RIGHT keys, then
the validate a selection with the OK key. To increase/decrease values, use
the UP and DOWN or LEFT and RIGHT keys, according to the situation and
validate with OK.
NOTICE
Installer Code
DHW Setting
DHW Operation Enabled
DHW Setpoint 140°F
DHW on Dierential 18°F
Warmstart Temperature 126°F
Warmstart Hysteresis 30°F
DHW Post Pump Time 2 min
DHW Setpoint
140°F
68°F 186°F
DHW Setpoint is the xed setpoint temperature during a do-
mestic hot water call.
Adjust the DHW Setpoint value using the LEFT or RIGHT
keys, then store the setting with the OK key.
Default: 140°F