Brochure
Thermal Output Maxi-Flo Heat Exchangers
Model
N
o.
GPM
Pressure Drop
Ft
Thermal
O
utput
Btu/hr
Hot Water Flow
GPM
Pressure Drop
Ft
Cold Water Flow
Heat Transfer
S
urface
Sq. Ft.
135,000
200,000
260,000
400,000
3
2
2
2
3
12
5
6
7
13
8
9
MF-135
MF-200
MF-260
MF-400
52
65
77
93
3
95,000
6
2 7
MF-80
77 6
5
6
8
Model
No.
A B C D
E F
Weight
lb
5 1/2" 13 1/2"
18 3/4"
23 3/4"
41 3/4"
5 1/8"
5 1/8"
5 1/8"
5 1/8"
5 1/2"
5 1/2"
5 1/2"
1"
1 1/2"
1 1/2"
2"
1"
1"
1 1/2"
2"
MF-135
MF-200
MF-260
MF-400
MF-80
(See below)
3"
8
11
14
24
6
3"
3"
3 1/2"
10"
3/4"
1
1
2
/
"
5
1
8
/
"
16
"
1
1
2
/
"
Boiler Connection
3/4" Boiler
Connection
Pool Connection
Pool Connection
5
1
2
/
"
A
B
D
E
E
Pool Connection
"F"
Pool Connection
"F"
All Bracket
Holes 1/4" I.D.
Boiler
Connection"C"
Boiler
Connection
"C"
Standard Features
• Constructed of high quality corrosion resistant stainless steel (AISI 316)
• Rolled formed to shape and then precision welded
• Specially designed built in flow restrictor to assure maximum heat exchange
• Designed to minimize pressure loss in the heating system
• Leak tested to assure that they are totally functionable
• Compact in size and require a minimum installation space - light weight
• Significant energy savings
• Available for all types of swimming pools, spas and hot tubs
• Equipped with stainless steel holding brackets
Dimensions
MF Model
Maxi-Flo 135
Cut-Away
MF 80 Model
Maximum working temperature 230ºF
Maximum working pressure: 140 psi (primary and secondary)