Installation Guide
(Continued from page 1)
IMPORTANT SAFETY INSTRUCTIONS
• Recommended to use LED-compatible Wall Dimmers with LED Power
Supplies. Tresco
®
Dimming LED Power Supplies are compatible with
forward phase, reverse phase, triac, MLV and ELV dimmers. For best
operation, use a Dimmer that can be programmed or has an adjustable
low-end dial such as the Lutron
®
C•L and Leviton IllumaTech
®
Universal
Dimmers. If you are unsure of dimmer compatibility, call
1-800-227-1171.
• Only install the Wall Dimmer on the input (line voltage) side of the
Power Supply.
Do not add a plug-in to input wires and attempt to dim a receptacle.
This can cause unwanted lighting effects (such as flickering), is
dangerous, and against NEC in certain applications.
Fixture does not illuminate • Check installation instructions and diagrams for all
components. Check if the system is wired correctly and
polarities are correct.
• Verify that a compatible constant voltage dimmable fixture is
installed.
• Verify if the power supply and fixture have the same voltage
specifications (i.e. 12V and 12V, etc.).
Fixture does not dim • Check that a compatible constant voltage dimmable fixture is
installed.
• Verify that a compatible dimming control is installed and
wired correctly.
Different fixture types do not dim in sync • Each fixture type has its own circuit design and may respond
differently when dimmed. Check that each fixture type is
installed on a separate dimmable power supply for best
performance.
Fixture is flickering • Verify that a compatible dimming control is installed. If
flickering occurs at low light levels install a compatible
dimming control with low-end dial adjustment
(i.e. Lutron
®
C•L).
• Check that a compatible constant voltage dimmable fixture is
installed.
• Check that all connections are properly secured.
• Check if fixture is receiving the correct input voltage.
• Check to make sure power supply is not wired to a dimmed
receptacle.
Fixture is steadily (continuous) ashing • Check that the power supply is not overloaded. An
overloaded power supply will cause the auto-reset to trip
repeatedly.
Installation trips main breaker • Check wiring for any short circuits. If breaker continues to
trip there may be a short in the power supply. Call customer
service for a replacement unit.
Troubleshooting
!
• Do not attempt to ground this unit. It is double-insulated. Keep? 7/17 Yes 8/17
• This unit can be mounted in any orientation, horizontal or vertical.
• Power Supply provides shut down protection against short circuit,
over loading, and over temperature. Unit automatically recovers after
fault condition is removed and after cooling.
• Intended for dry or damp locations only. Not intended for wet locations.
• Not intended for recessed installation in ceilings or softs.
• If any modication is made to the Power Supply, it will invalidate the
warranty and may render the product unsafe.
Tresco Lighting by Rev-A-Shelf
12400 Earl Jones Way
Louisville, KY 40299
T
el: 800-227-1171
Fax: 502-491-2215
Email: cservice@trescolighting.com
Web: www.trescolighting.com
I-DCE3060D-1, 11/19
I-PSREC-1 218 < This was the Proximity Form No.
LISTED
Save these instructions for future reference.
For technical assistance, call 1-800-227-1171
Page 2